Return to the previous level

Aluminum profiles for radiators

AI Server Liquid Cooling Plate Aluminum Profiles

AI server liquid cooling plate aluminum profiles - AI chip power consumption keeps climbing; single-chip thermal design power (TDP) has broken through from 700W to over 1000W, and liquid cooling has gone from 'optional' to 'mandatory'. The liquid cooling

Product Details

AI server liquid cooling plate aluminum profiles - AI chip power consumption keeps climbing; single-chip thermal design power (TDP) has broken through from 700W to over 1000W, and liquid cooling has gone from 'optional' to 'mandatory'. The liquid cooling plate is the core component of the liquid cooling system, and its manufacturing process is undergoing a technical iteration from welded to one-piece extrusion.

Shanghai Chuangsi Aluminum develops AI server liquid cooling plate aluminum profiles specifically for AI training servers, GPU computing clusters and data center liquid cooling systems, focusing on the core requirements of cold-plate liquid cooling for profiles: 'precise flow channels, uniform wall thickness, high flatness, pressure and corrosion resistance'. Adopting multi-channel integrated extrusion technology combined with CFD fluid simulation to optimize flow channel topology, the channels are smooth and seamless with low coolant flow resistance and uniform heat exchange. One-piece extrusion has no spliced welds, eliminating leakage risk at the source.

Core advantages at a glance:




Advantage DimensionTechnical IndicatorCustomer Value
One-Piece Extruded Flow ChannelsMulti-channel one-piece extrusion, no spliced weldsEliminates leakage risk at the source
High Heat Exchange EfficiencyOver 15% improvement vs welded typeMeets high-TDP chip heat dissipation needs
High FlatnessBase flatness ≤0.03mm/100mmTight fit with chips, reduces contact thermal resistance
Precise Flow ChannelsMin. channel width 3mm, dimensional tolerance ±0.05mmUniform coolant flow, efficient heat exchange
Uniform Wall ThicknessWall thickness uniformity ±0.1mmStable structural strength, good pressure resistance
Corrosion ResistantInner channel passivation / anodizing anti-corrosion treatmentSuitable for ethylene glycol aqueous solution, service life over 8 years
Helium Mass Spectrometry Leak DetectionLeak rate below 1x10⁻⁶ Pa·m³/sEnsures zero leakage under long-term operation

01 Quality Starts From Raw Materials

Produced from A00 primary aluminum ingot, containing no scrap aluminum, with uniform material and stable mechanical properties, ensuring sealing reliability of liquid cooling plates under long-term operation. Uses 6061-T6 high-strength aluminum alloy or 3003 rust-proof aluminum alloy.

02 One-Piece Extruded Flow Channel Forming

Combined with CFD fluid simulation to optimize flow channel topology, formed by precision die one-piece extrusion; channels are smooth and seamless. Compared with welded cold plates, one-piece extruded profiles have no weld leakage risk, over 15% higher heat exchange efficiency, and service life up to over 8 years.

03 High-Precision Quality Control

Using wire-EDM precision machining, cavity accuracy controlled within ±0.02mm. Base flatness ≤0.03mm/100mm, perfectly matching chip packaging and seal compression. Finished products can be tested with helium mass spectrometry leak detection, leak rate below 1x10⁻⁶ Pa·m³/s.

04 Corrosion-Resistant Enhancement Process

For common coolants such as ethylene glycol aqueous solution, inner channels can receive dedicated passivation or anodizing anti-corrosion treatment, improving electrochemical corrosion resistance by over 3 times. Cold plate service life is extended to over 8 years.

05 Full-Process Self-Management

Full process of mold development, hot extrusion, aging treatment and CNC precision machining is self-managed. Machining precision up to ±0.01-0.005mm, ensuring precise channel dimensions and uniform wall thickness.

Machining capability parameters:




ItemParameter / Description
Applicable ScenariosAI training servers, GPU computing clusters, data center liquid cooling systems
Available Materials6061-T6 high-strength aluminum alloy, 3003 rust-proof aluminum alloy
Executive StandardGB/T 6892-2023 high precision grade
Cross-Section RangeWidth 50mm-600mm
Flow Channel StructureSerpentine channels, split-flow, microchannels
Min. Flow Channel Width3mm
Wall Thickness Uniformity±0.1mm
Flow Channel Dimensional Tolerance±0.05mm
Mounting Datum Surface Tolerance±0.03mm
Base Flatness≤0.03mm/100mm
Overall Warpage≤0.05mm
Heat Exchange Efficiency ImprovementOver 15% improvement vs welded type
Service LifeOver 8 years
Leak RateBelow 1x10⁻⁶ Pa·m³/s (helium mass spectrometry leak detection)
Surface TreatmentHard anodizing, inner channel anti-corrosion passivation
Deep ProcessingFive-axis CNC precision milling, sealing surface grinding, drilling and tapping, helium mass spectrometry leak detection
Mold Development Lead Time7-10 days for sampling of standard structures
Bulk Lead Time12-20 days delivery after sample approval
MOQSupports 10-piece-level R&D sampling
Production LocationQingpu, Shanghai

One-piece extruded liquid cooling plate vs welded liquid cooling plate:




Comparison DimensionOne-Piece Extruded Liquid Cooling PlateWelded Liquid Cooling Plate
Flow Channel FormingOne-shot die forming, no spliced weldsWelded splicing, welds present
Leakage RiskEliminates leakage at the sourceWelds carry leakage risk
Heat Exchange EfficiencyOver 15% improvement vs welded typeGeneral
Flow Channel ContinuityChannels smooth and seamless, low flow resistanceChannels discontinuous at welds, local flow resistance increases
Service LifeOver 8 yearsRelatively short

AI server liquid cooling plate vs battery liquid cooling plate:




Comparison DimensionAI Server Liquid Cooling PlateBattery Liquid Cooling Plate
Application ScenariosAI training servers, GPU computing clusters, data centersNew energy vehicle power battery packs, energy storage battery packs
Flow Channel FeaturesMore precise channels, more compact structureLarge channel area, high flow
Core FocusLocal hot spot heat dissipation, low flow resistance designInter-cell temperature difference control, corrosion resistance
Flatness Requirements≤0.03mm/100mm≤0.1mm/m
MOQSupports 10-piece-level R&D sampling50kg

Typical application scenarios:

  • AI training server liquid cold plates

  • GPU computing cluster heat dissipation modules

  • Data center liquid cooling systems

  • Intelligent computing center server cold plates

  • Edge computing node liquid cooling components

  • HPC high-performance computing liquid cooling plates

FAQ (Frequently Asked Questions)

Q1: What is the difference between one-piece extruded liquid cooling plates and welded liquid cooling plates?

A: The flow channels of one-piece extruded liquid cooling plates are formed in one shot by die with no spliced welds, eliminating leakage risk at the source. Channels are smooth and seamless with low coolant flow resistance and uniform heat exchange; heat exchange efficiency is over 15% higher than welded cold plates, and service life can reach over 8 years. Welded cold plates carry weld leakage risk, and channels are discontinuous at welds with increased local flow resistance. As AI chip power consumption keeps climbing and single-chip thermal design power (TDP) has broken through from 700W to over 1000W, liquid cooling has gone from 'optional' to 'mandatory'; one-piece extruded liquid cooling plates are the mainstream solution for AI server liquid cooling.

Q2: What types of flow channel structures can be customized for AI server liquid cooling plates?

A: We can customize various internal flow channel structures such as serpentine channels (for uniform heat dissipation needs), split-flow channels (for high-flow low-resistance needs), and microchannel channels (for high heat flux density scenarios). Combined with CFD fluid simulation to optimize flow channel topology, we control flow resistance within a reasonable range while meeting heat dissipation needs. Min. channel width 3mm, channel dimensional tolerance ±0.05mm.

Q3: Why does AI server liquid cooling plate base flatness need to be ≤0.03mm/100mm?

A: The liquid cooling plate must fit tightly against the chip or heat source surface, and flatness directly determines the contact thermal resistance. Base flatness ≤0.03mm/100mm ensures gap-free contact between the liquid cooling plate and the chip for minimum contact thermal resistance. Insufficient flatness causes local poor contact and heat accumulation; for AI chips with TDP over 1000W, local hot spots may cause chip throttling or even damage.

Q4: How does the AI server liquid cooling plate guarantee no long-term leakage?

A: Leakage is prevented through three lines of defense: first, at the design stage - one-piece extrusion with no spliced welds eliminates weld leakage at the source; second, at the machining stage - wire-EDM precision machining with cavity accuracy controlled within ±0.02mm; third, at the inspection stage - finished products are tested with helium mass spectrometry leak detection, leak rate below 1x10⁻⁶ Pa·m³/s. The three lines of defense ensure zero leakage over long-term operation, with service life up to over 8 years.

Q5: What is the MOQ and lead time for AI server liquid cooling plates?

A: Supports 10-piece-level R&D sampling, suitable for early validation and testing of AI server liquid cooling solutions. Mold development lead time for standard structures is 7-10 days for sampling; bulk delivery is 12-20 days after sample approval. Liquid cooling projects usually have tight lead times, and we support expedited scheduling. The factory is located in Qingpu, Shanghai, deeply serving the Lin'gang, Zhangjiang, Suzhou and other computing industry clusters.

Get Your Solution Now

Call Manager Du: 13611846009

Provide drawings or technical requirements; our engineering team gives feasibility assessment and mold development plan within 2 hours.

Free technical consultation | Complex cross-section evaluation | Direct from source factory


GET A QUOTE

Once you have submitted your requirements, we will contact you as soon as possible regarding your product inquiry.:AI Server Liquid Cooling Plate Aluminum Profiles

Product Inquiry

AI Server Liquid Cooling Plate Aluminum Profiles